Description: Upgrade Failed Security Feature Active 03-329-00 Upgrade failure due to active security feature Software upgrade request during while a security feature is active. The upgrade process is aborted and the printer resets. If configured, an email alert is sent and upgrade report printed. An entry is made in Upgrade History log.
Remedy: Perform GP 9 to reload system software. The error persists. Y↓N→Perform SCP 6 Final Actions. Perform GP 9 to reload system software.
Description: Communication Fault with NC 03-331-00 Main controller board cannot communicate with network controller. Status code 03- 563 is raised with this fault code. 03-332-00 Unable to reestablish communications with the network controller after 12 minutes. Status code 03-518 is raised with this fault code.
Remedy: Cycle system power. The error persists. Y↓N→Perform SCP 6 Final Actions. Perform GP 9 to reload system software. The error persists. Y↓N→Perform SCP 6 Final Actions. Install new components as necessary: • IP Board
Description: Communication Fault with UI 03-346-00 Unable to reestablish communication with the Control Panel after 30 seconds. Status code 03-520 is raised with the fault code. 03-347-00 IP Board cannot communicate with the Control Panel. Continue to attempt to establish communication for 30 seconds. Status code 03-521 is raised with the fault code.
Remedy: Cycle system power. The error persists. Y↓N→Perform SCP 6 Final Actions Perform GP 9 to reload system software. The error persists. Y↓N→Perform SCP 6 Final Actions Install new components as necessary: • IP Board • Control Panel
Description: POST Boot Failure 03-380-00 POST boot failure. Fault assumes no Control Panel communications. NOTE: PWS communication for diagnostic purposes available.
Remedy: Cycle system power. The error persists. Y↓N→Perform SCP 6 Final Actions Perform GP 9 to reload system software. The error persists. Y↓N→Perform SCP 6 Final Actions Install new components as necessary: • IP Board • Control Panel
Remedy: Cycle system power. The error persists. Y↓N→Perform SCP 6 Final Actions Perform GP 9 to reload system software. The error persists. Y↓N→Perform SCP 6 Final Actions Install new components as necessary: • IP Board • Control Panel
Remedy: Cycle system power. The error persists. Y↓N→Perform SCP 6 Final Actions Perform GP 9 to reload system software. The error persists. Y↓N→Perform SCP 6 Final Actions Install new components as necessary: • SD Card • IP Board
Description: SIM Card Serial Number Mismatch 03-398-00 SIM card serial number did not match the serial number contained in system CCS NVM. Status code 22-559 is raised with this fault code.
Remedy: Cycle system power. The error persists. Y↓N→Perform SCP 6 Final Actions Perform GP 9 to reload system software. The error persists. Y↓N→Perform SCP 6 Final Actions Install new components as necessary: • SD Card • IP Board
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.