Description: Unable to Obtain Client RPC Handle 16-030-19 Unable to obtain client RPC handle to EJS NOTE: Status codes 03-518 and 16-502 are raised with this fault code.
Remedy: If a single occurrence, the network controller automatically retries. The error persists. Y↓N→Perform SCP 6 Final Actions. Cycle system power. The error persists. Y↓N→Perform SCP 6 Final Actions. Perform GP 9 to reload system software.
Description: Invalid Event Notification Received 16-031-09 Invalid event notification received NOTE: Status codes 03-518 and 16-502 are raised with this fault code.
Remedy: If a single occurrence, the network controller automatically retries. The error persists. Y↓N→Perform SCP 6 Final Actions. Cycle system power. The error persists. Y↓N→Perform SCP 6 Final Actions. Perform GP 9 to reload system software.
Description: NVM Connection Failure / Pthread Create Error 16-032-19 NVM Connection Failure 16-039-00 Pthread Create Error NOTE: Status codes 03-518 and 16-502 are raised with these fault codes.
Remedy: If a single occurrence, the network controller automatically retries. The error persists. Y↓N→Perform SCP 6 Final Actions. Cycle system power. The error persists. Y↓N→Perform SCP 6 Final Actions. Perform GP 9 to reload system software.
Description: Unable to Set Binding 16-048-09 Unable to set binding NOTE: Status codes 03-518 and 16-502 are raised with this fault code.
Remedy: If a single occurrence, the network controller automatically retries. The error persists. Y↓N→Perform SCP 6 Final Actions. Cycle system power. The error persists. Y↓N→Perform SCP 6 Final Actions. Perform GP 9 to reload system software
Description: Cannot Set NC Client Binding 16-048-99 Unable to set client binding
Remedy: If a single occurrence, the network controller automatically retries. The error persists. Y↓N→Perform SCP 6 Final Actions. Cycle system power. The error persists. Y↓N→Perform SCP 6 Final Actions. Perform GP 9 to reload system software.
Description: Cannot Send Registration Event 16-150-09 Cannot send Registration Event NOTE: Status codes 03-518 and 16-502 are raised with this fault code.
Remedy: Cycle system power. The error persists. Y↓N→Perform SCP 6 Final Actions. Perform GP 9 to reload system software.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.