Description: Fuser Exhaust Fan Fail 42-330-00 Fuser Exhaust Fan Fail NOTE: Status codes 03-561 and 04-563 are raised with this fault code.
Remedy: Use dC330 code 42-001 to test the Rear Fan. The Fan rotates. Y↓N→Check the Fan harness and connections between the Fan and LVPS. The wiring is good. Y↓N→Secure the connections or repair the Fan harness as necessary. Install new components as necessary: • Rear Fan • LVPS Go to SCP 6 and complete the Final Actions.
Code: 45-301-00 ... 45-305-00
Description: IOT I/F Error 41-301-00 I/F Ack Unreceived High 41-302-00 I/F Ack Unreceived Low 41-303-00 I/F Received Buffer Overflow 41-304-00 I/F Send Buffer High Overflow 41-305-00 I/F Send Buffer Low Overflow NOTE: Status codes 03-561 and 04-566 are raised with this fault code
Remedy: Do not replace the MCU and IP Boards at the same time. Replace or check the IP Board first, then cycle system power before replacing the MCU Board. Simultaneous replacement of IP and MCU Boards will make the printer inoperable. Cycle system power. The error persists. Y↓N→Go to SCP 6 and complete the Final Actions. Check the wiring and connections between the MCU and IP Boards. The wiring is good. Y↓N→Re-seat loose connectors or install new components as necessary: • MCU Board • IP Board Go to SCP 6 and complete the Final Actions
Code: 61-020-00 ... 61-340-00
Description: ROS Error 61-020-00 ROS Rotation fail 61-327-00 ROS Warm up fail 61-340-00 ROS LD fail NOTE: Status codes 03-561 and 06-515 are raised with this fault code.
Remedy: Cycle system power. The error persists. Y↓N→Go to SCP 6 and complete the Final Actions. Use dC330 code 61-001 to test the Laser Unit motor. The Laser Unit motor rotates. Y↓N→Replace the Laser Unit Replace the IP Board
Code: 62-311-00 ... 62-389-00
Description: IIT Scan Error 62-311-00 IISS LOGIC Fail. Status code 03-557 is raised with this fault code. 62-317-00 IIT Video Over-run 62-318-00 IIT Scanning Timing error 62-319-00 PLL Lock Time Out error 62-321-00 Scan failure 62-322-00 S/W Parameter error 62-360-00 CRG Position Fail 62-345-00 IISS EEPROM Fail 62-362-00 X Hard Fail 62-380-00 AGC Fail 62-386-00 AOC Fail 62-389-00 CRG Over Run Fail NOTE: Status code 14-517 is raised with these fault codes.
Remedy: Cycle system power. The error persists. Y↓N→Go to SCP 6 and complete the Final Actions. Check connections and wiring between the IIT Assembly (Scanner) and IP Board. The wiring is good. Y↓N→Repair or reseat wiring as needed. Install new components as necessary: • IIT Control Board • IIT Assembly • IP Board
Code: 62-316-00
Description: DADF Motor Fail 62-316-00 DADF Motor Fail NOTE: Status code 14-517 is raised with this fault code.
Remedy: Cycle system power. The error persists. Y↓N→Go to SCP 6 and complete the Final Actions. Check connections and wiring between the DADF Assembly and IP Board. The wiring is good. Y↓N→Repair or reseat wiring as needed. Install new components as necessary: • DADF Assembly • IIT Control Board • IP Board
Code: 62-790-00
Description: PreIPS XFail 62-790-00 PreIPS XFail. Bank note detected.
Remedy: Cycle system power. The error persists. Y↓N→Go to SCP 6 and complete the Final Actions. Check connections and wiring between the IIT Assembly and IP Board. The wiring is good. Y↓N→Repair or reseat wiring as needed. Install new components as necessary: • IIT Assembly • IIT Control Board • IP Board
Code: 70-099-00
Description: I/F IOTFED Communication 70-099-00 I/F IOTFED Communication NOTE: Status codes 03-561 and 92-530 are raised with this fault code.
Remedy: Cycle system power. The error persists. Y↓N→Go to SCP 6 and complete the Final Actions. Remove the printer from the Optional Feeder. Check feeder option connector continuity. The harnesses are undamaged. Y↓N→Repair the damaged option harness. lnstall new components as necessary: • Feeder Board • MCU Board
Code: 71-101-00
Description: Tray1 Misfeed Jam 71-101-00 Tray1 Misfeed Jam NOTE: Status code 07-501 is raised with this fault code.
Remedy: Check the Nudger, Feed, and Retard Rollers for excessive wear or contamination. The rollers are undamaged and clean. Y↓N→Clean or replace the rollers. Use dC330 code 071-102 to test the Registration Sensor. The sensor signal changes. Y↓N→Check the connection between the HVPS and MCU Board. The connection is secure. Y↓N→Secure the connection. Replace the HVPS . Use dC330 code 071-005 to test the Feed Clutch. The clutch activates. Y↓N→Replace the Feed Clutch . Use dC330 code 071-001 to test the Main Drive Assembly. The motor rotates. Y↓N→Replace the Main Drive Assembly . lnstall new components as necessary: • Feed Rollers • MCU Board