Description: IOT Front Cover Open RAP The IOT Front Cover is open.
Remedy: Check the opening/closing of the IOT Front Cover. The Front Cover can be opened/closed. Y↓N→Reinstall the Front Cover. Check the installation of the Front Cover Interlock Switch. The Front Cover Interlock Switch is installed correctly. Y↓N→Install the Front Cover Interlock Switch correctly. Execute Component Control [071-303 Front Cover Interlock Switch]. Open/close the IOT Front Cover. The display changes. Y↓N→Check the connections of P/J121 and P/J405. P/J121 and P/J405 are connected correctly. Y↓N→Connect P/J121 and P/J405. Check the wire between J405 and J121 for an open circuit or a short circuit. The wire between J405 and J121 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Check the conductivity of the Front Cover Interlock Switch (PL 10.1) between J405-3 and J405-4. The wire between J405-3 and J405-4 is connecting successfully when the Front Cover is closed, and is insulated when the cover is open. Y↓N→Replace the Front Cover Interlock Switch (PL 10.1). Replace the MCU PWB (PL 9.1). Replace the MCU PWB (PL 9.1).
Code: 077-301
Description: Left Hand Interlock Open RAP The L/H Cover Assembly is open.
Remedy: Check opening/closing of the L/H Cover Assembly. The L/H Cover Assembly can be opened/closed. Y↓N→Reinstall the L/H Cover Assembly (PL 2.6). Check the installation of the L/H Cover Interlock Switch. The L/H Cover Interlock Switch is installed correctly. Y↓N→Install the L/H Cover Interlock Switch correctly. Execute Component Control [071-300 L/H Cover Interlock Switch]. Open and close the L/H Cover Assembly. The display changes. Y↓N→Check the connections of P/J120 and P/J405. P/J120 and P/J405 are connected correctly. Y↓N→Connect P/J120 and P/J405. Check the wire between J405 and J120 for an open circuit or a short circuit. The wire between J405 and J120 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Check the conductivity of the L/H Cover Interlock Switch (PL 2.6) between J405-1 and J405-2. The wire between J405-1 and J405-2 is connecting successfully when the L/H Cover Assembly is closed, and is insulated when the cover is open. Y↓N→Replace the L/H Cover Interlock Switch (PL 2.6). Measure the voltage between the MCU PWB P405-2 (+) and GND (-). The voltage is approx. +24VDC. Y↓N→Measure the voltage between the MCU PWB P400-1 (+) and GND (-). The voltage is approx. +24VDC. Y↓N→Check the connections of P/J526 and P/J400. P/J526 and P/J400 are connected correctly. Y↓N→Connect P/J526 and P/J400. Check the wire between J526 and J400 for an open circuit or a short circuit. The wire between J526 and J400 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Check the connections of P/J521, P/J523 and P/J300, P/J301. P/J521, P/ J523 and P/J300, P/J301 are connected correctly. Y↓N→Connect P/J521, P/J523 and P/J300, P/J301. Check the wire between J521, J523 and J300, J301 for an open circuit or a short circuit. The wire between J521, J523 and J300, J301 are conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the ESS PWB P301-3 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the ESS PWB (PL 9.2). Replace the Power Unit (PL 9.1). Replace the MCU PWB (PL 9.1). Replace the MCU PWB (PL 9.1). Replace the MCU PWB (PL 9.1).
Code: 077-305
Description: Tray Module Left Hand Cover Interlock Open RAP • The 2TM Cover is open. • The TTM Cover is open.
Remedy: Check opening/closing of the Left Cover of the 2TM or TTM. The Left Cover of the 2TM or TTM can be opened/closed. Y↓N→Reinstall the Left Cover of the 2TM or TTM (PL 12.4/PL 13.7). Check the installation of the Tray Module Interlock Switch. The Tray Module interlock Switch is installed correctly. Y↓N→Install the Tray Module interlock Switch (PL 12.4/PL 13.7) correctly. Execute Component Control [071-301 Tray Module Left Cover Interlock Switch]. Open and close the Left Cover of the 2TM or TTM. The display changes. Y↓N→Check the connections of P/J554, FS812 and FS813. P/J554, FS812 and FS813 are connected correctly. Y↓N→Connect P/J554, FS812 and FS813. Check the wire between J554-2 and FS812, and between J554-1 and FS813 for an open circuit or a short circuit. The wires between J554-2 and FS812, and between J554-1 and FS813 are conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Check the conductivity of the Tray Module Left Cover Interlock Switch (PL 12.4/PL 13.7) between FS813 and FS812. The wire between FS813 and FS812 is connecting successfully when the 2TM Cover or TTM Cover is closed, and is insulated when the cover is open. Y↓N→Replace the Tray Module Left Cover Interlock Switch (PL 12.4/PL 13.7). Replace the Tray Module PWB (PL 12.6/PL 13.8). Replace the Tray Module PWB (PL 12.6/PL 13.8).
Code: 077-307
Description: DUP Cover Open RAP The DUP Cover is open.
Remedy: Check opening/closing of the DUP Cover. The DUP Cover can be opened/closed. Y↓N→Reinstall the DUP Cover. Check the installation of the Duplex Open Switch (PL 8.1). The Duplex Open Switch is installed correctly. Y↓N→Install the Duplex Open Switch (PL 8.1) correctly. Execute Component Control [071-305 Duplex Open Switch]. Open and close the DUP Cover. The display changes. Y↓N→Check the connections of P/J124 and P/J541. P/J124 and P/J541 are connected correctly. Y↓N→Connect P/J124 and P/J541. Check the wire between J124 and J541 for an open circuit or a short circuit. The wire between J124 and J541 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Check the conductivity of the Duplex Open Switch (PL 8.1) between J541-4 and J541-5. The wire between J541-4 and J541-5 is connecting successfully when the DUP Cover is closed, and is insulated when the cover is open. Y↓N→Replace the Duplex Open Switch (PL 8.1). Replace the MCU PWB (PL 9.1). Replace the MCU PWB (PL 9.1).
Code: 077-308
Description: Left Hand HIGH Interlock Open RAP The L/H-H Cover is open.
Remedy: Check opening/closing of the IOT L/H-H Cover. The IOT L/H-H Cover can be opened/ closed. Y↓N→Reinstall the IOT L/H-H Cover. Check the installation of the Exit 2 Interlock Switch. The Exit 2 Interlock Switch is installed correctly. Y↓N→Install the Exit 2 Interlock Switch correctly. Execute Component Control [071-304 Exit 2 Interlock Switch]. Open/close the IOT L/H-H Cover. The display changes. Y↓N→Check the connections of P/J434, P/J116, P606, J606 and SJ1. The P/J434, P/J116, P606, J606 and SJ1 are connected correctly. Y↓N→Connect P/J434, P/J116, P606, J606 and SJ1. Check the wire between J434 and J116 for an open circuit or a short circuit. The wire between J434 and J116 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Check the conductivity of the Exit 2 Interlock Switch (PL 6.4) between J434-12 and J434- 13. The wire between J434-12 and J434-13 is connecting successfully when the IOT L/H-H Cover is closed, and is insulated when the cover is open. Y↓N→Replace the Exit 2 Interlock Switch (PL 6.4). Replace the MCU PWB (PL 9.1). Replace the MCU PWB (PL 9.1).
Code: 077-309
Description: Left Hand Low Interlock Open RAP The L/H Lower Cover is open.
Remedy: Check opening/closing of the L/H Lower Cover. The L/H Lower Cover can be opened/ closed. Y↓N→Reinstall the L/H Lower Cover (PL 2.5). Check the installation of the L/H Lower Cover Interlock Switch. The L/H Lower Cover Interlock Switch is installed correctly. Y↓N→Install the L/H Lower Cover Interlock Switch (PL 2.5) correctly. Execute Component Control [071-302 L/H Lower Cover Interlock Switch]. Open/close the L/H Lower Cover. The display changes. Y↓N→Check the connections of P/J106 and P/J410. P/J106 and P/J410 are connected correctly. Y↓N→Connect P/J106 and P/J410. Check the wire between J106 and J410 for an open circuit or a short circuit. The wire between J106 and J410 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Check the conductivity of the L/H Lower Cover Interlock Switch (PL 2.5) between J410-11 and J410-12. The wire between J410-11 and J410-12 is connecting successfully when the L/H Lower Cover is closed, and is insulated when the cover is open. Y↓N→Replace the L/H Lower Cover Interlock Switch (PL 2.5). Replace the MCU PWB (PL 9.1). Replace the MCU PWB (PL 9.1).
Code: 077-310
Description: Controller Failed to send image RAP The MCU PWB did not receive the ESS PWB image-ready signal within the specified time.
Remedy: Check the ROM version by executing NVM[740-007 ROM Version]. The ROM is the latest version. Y↓N→Replace the ROM with the latest version. Replace the MCU PWB (PL 9.1). If the problem persists, replace the ESS PWB (PL 9.2).
Code: 077-329
Description: Main Motor Stop Error RAP Due to MCU PWB control failure, the Main Motor does not stop when no paper is being fed.
Remedy: Check the ROM version by executing NVM [740-007 ROM Version]. The ROM is the latest version. Y↓N→Replace the ROM with the latest version. Replace the MCU PWB (PL 9.1).