Description: USB Memory Removal Error USB memory is removed while memory reading job is being executed. • 016-791: USB Memory Removal Error • 016-795: File Format Error • 016-797: File Read Error
Causes: • IP Board, PL7.1.9/PL7.1.16 • MCU Board, PL7.2.2
Remedy: 1 Reseat all connections on the IP Board and MCU Board. Does the error persist? Go to step 2. Complete. 2 Replace the IP Board. Does the error persist? Go to step 3. Complete. 3 Replace the MCU Board. Complete.
Causes: • IP Board, PL7.1.9/PL7.1.16 • MCU Board, PL7.2.2
Remedy: 1 Reseat all connections on the IP Board and MCU Board. Does the error persist? Go to step 2. Complete. 2 Replace the IP Board. Does the error persist? Go to step 3. Complete. 3 Replace the MCU Board. Complete.
Code: 016-920
Description: Wireless Error
Causes: • IP Board, PL7.1.9B • MCU Board, PL7.2.2
Remedy: 1 Reseat all connections on the IP Board and MCU Board. Does the error persist? Go to step 2. Complete. 2 Replace the IP Board. Does the error persist? Go to step 3. Complete. 3 Replace the MCU Board. Complete.
Code: 016-930, 016-931
Description: USB Host Error. An unsupported USB memory device was attached to the USB port. • 016-930: USB Host Full • 016-931: USB Host Error
Causes:
Remedy: Unplug the unsupported device.
Code: 016-981
Description: Collate Full The print job is too large.
Causes: • IP Board, PL7.1.9 • MCU Board, PL7.2.2
Remedy: 1 Reseat all connectors on the IP Board and the MCU Board. Does the error persist? Go to step 2. Complete. 2 Replace the IP Board. Does the error persist when the power is turned on? Replace the MCU Board. Complete.
Code: 016-985, 017-970, 017-988
Description: Mail Size Limits Error, PCScan Time Out, Memory Full. • 016-985: Mail Size Limits Error • 017-970: PCScan Time Out • 017-988: Memory Full
Causes: • IP Board, PL7.1.9 • MCU Board, PL7.2.2
Remedy: 1 Reseat all connectors on the IP Board and the MCU Board. Does the error persist? Go to step 2. Complete. 2 Replace the IP Board. Does the error persist when the power is turned on? Replace the MCU Board. Complete.
Causes: • IP Board, PL7.1.9 • MCU Board, PL7.2.2
Remedy: 1 Reseat all connectors on the IP Board and the MCU Board. Does the error persist? Go to step 2. Complete. 2 Replace the IP Board. Does the error persist when the power is turned on? Replace the MCU Board. Complete.
Code: 017-990
Description: Scanner Calibration Failure Calibration of the Scanner failed.
Remedy: 1 Reseat all connectors on the IP Board and the MCU Board. Does the error persist? Go to step 2. Complete. 2 Replace the IP Board. Does the error persist? Replace the MCU Board, then go to step 3. Complete. 3 Does the error persist? Replace the Scanner. Complete.