Code: 05-121-00

Description: CVT-DADF Feed Sensor On Jam 05-121-00 The feed sensor is not turned on in the time specified. In Duplex mode, the feed sensor is not turned on after a specified time
Remedy: Open the DADF Top Cover and clean the area surrounding the DADF Pick-up Assembly. The error persists. Y↓N→Perform SCP 6 Final Actions. Clean or replace the DADF Pick-up Assembly . The error persists. Y↓N→Perform SCP 6 Final Actions. Install new components as necessary: • DADF Pick-up Assembly • DADF Assembly • IIT Control Board

Code: 05-900-00

Description: ADF Sensor Static Jam 05-900-00 The DADF Top Cover interlock switch is opened during DADF operation. Paper remains in paper path after cover is closed..
Remedy: Check the DADF Top Cover properly actuates the interlock switch. The error persists. Y↓N→Perform SCP 6 Final Actions. Replace the DADF Assembly .

Code: 05-940-00

Description: DADF No Original Fail 05-940-00 Original has been removed. Status code 05-535 is raised with this fault code.
Remedy: Open the DADF Top Cover and clean the area surrounding the DADF Pick-up Assembly. The error persists. Y↓N→Perform SCP 6 Final Actions. Clean or replace the DADF Pick-up Assembly . The error persists. Y↓N→Perform SCP 6 Final Actions. Install new components as necessary: • DADF Pick-up Assembly • DADF Assembly • IIT Control Board

Code: 10-311-00 ... 10-376-00

Description: Fuser Thermal Error 10-311-00 Center STS sensor burnout detection 10-321-00 Hard Relay OFF 10-324-00 Sub lamp ON consecutive errors 10-326-00 Cool Down Timeout 10-328-00 Warming up - timeout 10-334-00 STS center-side sensor failure 10-337-00 Heat Roll Paper twine Error 10-338-00 Main lamp ON consecutive errors 10-372-00 Center STS High-temperature anomaly 10-373-00 Side STS Disconnection abnormality 10-374-00 Side STS High-temperature anomaly 10-375-00 Center STS Low-temperature anomaly 10-376-00 Side STS Low-temperature anomaly
Remedy: Cycle system power. The error persists. Y↓N→Go to SCP 6 and complete the Final Actions. Replace the Fuser

Code: 10-420-00, 10-421-00

Description: Fuser End of Life 10-420-00 Fuser Assy Near Life. Status code 10-524 is raised with this fault code. 10-421-00 Fuser Assy Life End. Status code 10-523 is raised with this fault code.
Remedy: Check the Fuser life count. Fuser life count is at or near end of life. Y↓N→Cycle system power. The error message is displayed. Y↓N→Reassemble and perform SCP 6 Final Actions. Replace the Fuser . Replace the Fuser

Code: 10-902-00

Description: Fuser Missing
Remedy: Reseat the Fuser. The error persists. Y↓N→Go to SCP 6 and complete the Final Actions. Replace the Fuser .

Code: 10-903-00

Description: Main Error updating data NOTE: Status codes 03-561 and 10-527 are raised with this fault code.
Remedy: Cycle system power. The error persists. Y↓N→Go to SCP 6 and complete the Final Actions. Replace the Fuser .

Code: 12-930-00

Description: Exit Tray Full
Remedy: Cycle system power. The error persists. Y↓N→Go to SCP 6 and complete the Final Actions. Use dC330 code 71-122 to check Full Stack Sensor operation. The sensor signal changes. Y↓N→Remove the Exit Chute Assembly to check the sensor, acutator, and harness. The sensor is connected and the harness undamaged. Y↓N→Replace the Full Stack Sensor or repair the harness. If the actuator is damaged, replace the Exit Chute Assembly. Replace the MCU Board Install new components as necessary: • Full Stack Sensor • Exit Chute Assembly • MCU Board