Description: Cannot Create RPC With ENS 16-000-00 Format Service Non Shutdown NC Faults 16-000-01 ENS Service Non Shutdown NC Faults 16-000-09 Cannot create RPC connection with ENS 16-000-14 Cannot create RPC connection with ENS 16-000-19 Cannot create RPC connection with ENS 16-000-26 Cannot create RPC connection with ENS NOTE: Status codes 03-518 and 16-502 are raised with these fault codes.
Remedy: If a single occurrence, the network controller automatically retries. The error persists. Y↓N→Perform SCP 6 Final Actions. Perform GP 9 to reload system software.
Description: Unable to do Startup Synchronization 16-001-09 Unable to do startup synchronization 16-001-14 Unable to do startup synchronization 16-001-19 Unable to do startup synchronization 16-001-26 Unable to Start up and synchronize with SC 16-001-47 Unable to do startup synchronization 16-001-90 Unable to do startup synchronization NOTE: Status codes 03-518 and 16-502 are raised with these fault codes.
Remedy: If a single occurrence, the network controller automatically retries. The error persists. Y↓N→Perform SCP 6 Final Actions. Cycle system power. The error persists. Y↓N→Perform SCP 6 Final Actions. Perform GP 9 to reload system software.
Description: Unable to Register as RPC Server 16-002-09 Unable to Register as RPC server 16-002-14 Unable to Register as RPC server 16-002-19 Unable to Register as an RPC server 16-002-26 Could not become an RPC Server 16-002-46 Unable to Register as an RPC server NOTE: Status codes 03-518 and 16-502 are raised with these fault codes.
Remedy: If a single occurrence, the network controller automatically retries. The error persists. Y↓N→Perform SCP 6 Final Actions. Cycle system power. The error persists. Y↓N→Perform SCP 6 Final Actions. Perform GP 9 to reload system software.
Description: Too Many IPC Handles 16-003-09 Too many IPC Handles 16-003-14 Too many IPC Handles 16-003-19 Too many IPC Handlers 16-003-90 Utility Insert Handler Failure NOTE: Status codes 03-518 and 16-502 are raised with these fault codes.
Remedy: If a single occurrence, the network controller automatically retries. The error persists. Y↓N→Perform SCP 6 Final Actions. Cycle system power. The error persists. Y↓N→Perform SCP 6 Final Actions. Perform GP 9 to reload system software
Description: RPC Failure to Register 16-004-14 RPC Connect Failure to NC Registration Service 16-004-19 RPC Connect Failure to NC Registration Service 16-004-26 RPC Connect Failure to NC Registration Service 16-004-46 RPC Failed to Connect to with NC Service 16-005-14 RPC Call Failure to NC Registration Service 16-005-19 RPC Call Failure to NC Registration Service 16-005-26 RPC Call Failure to NC Registration Service 16-005-46 RPC Failed to Register with NC Service 16-005-68 RPC Failed to Register with NC Service 16-005-90 RPC call to NC Registration Failed 16-005-92 RPC Failed to Register with NC Service NOTE: Status codes 03-518 and 16-502 are raised with these fault codes.
Remedy: If a single occurrence, the network controller automatically retries. The error persists. Y↓N→Perform SCP 6 Final Actions. Cycle system power. The error persists. Y↓N→Perform SCP 6 Final Actions. Perform GP 9 to reload system software.
Description: Cannot Register for Events 16-006-09 Cannot register for events 16-006-19 Cannot register for events NOTE: Status codes 03-518 and 16-502 are raised with these fault codes.
Remedy: Cycle system power. The error persists. Y↓N→Perform SCP 6 Final Actions. Perform GP 9 to reload system software.
Description: Invalid IPC / RPC Data 16-007-92 Invalid RPC Data Received 16-009-09 Invalid IPC Data Received 16-010-14 Unable to send IPC 16-010-99 Unable to send IPC
Remedy: If a single occurrence, the network controller automatically retries. The error persists. Y↓N→Perform SCP 6 Final Actions. Cycle system power. The error persists. Y↓N→Perform SCP 6 Final Actions. Perform GP 9 to reload system software.
Description: Copier Synchronization Error 16-013-14 Digital Copier ENS synchronization error 16-014-14 Digital Copier ENS registration error NOTE: Status codes 03-518 and 16-502 are raised with these fault codes.
Remedy: Cycle system power. The error persists. Y↓N→Perform SCP 6 Final Actions. Perform GP 9 to reload system software.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.